Description

The Edwards SIGA-PHCD detector brings advanced multisensing technology to a practical design that increases efficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities. Continuous self-diagnostics ensure reliability over the long haul, while environmental compensation helps reduce maintenance costs.

In general, the Edwards SIGA-PHCD provides the best of all worlds with comprehensive life safety monitoring. The combination of optical smoke detection with rate-of-rise heat sensing technology provides efficient identification of smoldering fires, as well as fast flaming fires. With the added element of CO monitoring, this detector pulls double duty: continually monitoring the environment for signs of fire — as well as its invisible yet deadly companion, carbon monoxide.

Besides, like all Signature Series detectors, the Edwards Est SIGA-PHCD gathers analog information from its sensing elements and converts this data into digital signals. To make an alarm decision, the detector’s onboard microprocessor measures as well as analyze smoke and heat sensor readings and compares this information to historical data. Digital filters remove signal patterns that are not typical of fires, thus virtually eliminating unwanted alarms. The detector also analyzes the smoke and heat sensors independently from the CO sensor to determine whether to initiate a fire alarm, a life safety CO alarm, or both.

Features / Specifications

  • Integrates optical smoke with rate-of-rise heat sensing and
    carbon monoxide detection
  • Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration
  • Sensor Markings Provide Easy Testing Identification
  • Automatic device mapping
  • Two levels of environmental compensation
  • Two levels of dirty detector warning
  • Twenty pre-alarm settings
  • Five sensitivity settings
  • Electronic addressing
  • Standard, relay, fault isolator, and audible mounting bases

 

 

Additional information

Weight 1 lbs
Dimensions 5 × 5 × 5 in
Brand

Reviews

There are no reviews yet.

Be the first to review “Edwards SIGA-PHCD Multi-Sensor Smoke and Heat”

Your email address will not be published. Required fields are marked *

Payment & Security

Your Payment information is processed securely. We do not store credit card details, nor have access to your credit card information.

Edwards SIGA-PHCD Multi-Sensor Smoke and Heat

SKU SIGA-PHCD Category Tags , Brand:
Price:
$92.00
Shipping calculated at checkout | Purchase & earn 92 points!
Stock:
219+ units in stock - ready to ship.
Quantity:

FAST SHIPPING

Orders ship same day

HUGE INVENTORY

Thousands of parts in stock

TRUSTED BY CONTRACTORS

Reliable products & service

24/7 ORDERING

Order anytime, anywhere

Description

The Edwards SIGA-PHCD detector brings advanced multisensing technology to a practical design that increases efficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities. Continuous self-diagnostics ensure reliability over the long haul, while environmental compensation helps reduce maintenance costs.

In general, the Edwards SIGA-PHCD provides the best of all worlds with comprehensive life safety monitoring. The combination of optical smoke detection with rate-of-rise heat sensing technology provides efficient identification of smoldering fires, as well as fast flaming fires. With the added element of CO monitoring, this detector pulls double duty: continually monitoring the environment for signs of fire — as well as its invisible yet deadly companion, carbon monoxide.

Besides, like all Signature Series detectors, the Edwards Est SIGA-PHCD gathers analog information from its sensing elements and converts this data into digital signals. To make an alarm decision, the detector’s onboard microprocessor measures as well as analyze smoke and heat sensor readings and compares this information to historical data. Digital filters remove signal patterns that are not typical of fires, thus virtually eliminating unwanted alarms. The detector also analyzes the smoke and heat sensors independently from the CO sensor to determine whether to initiate a fire alarm, a life safety CO alarm, or both.

Features / Specifications

  • Integrates optical smoke with rate-of-rise heat sensing and
    carbon monoxide detection
  • Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration
  • Sensor Markings Provide Easy Testing Identification
  • Automatic device mapping
  • Two levels of environmental compensation
  • Two levels of dirty detector warning
  • Twenty pre-alarm settings
  • Five sensitivity settings
  • Electronic addressing
  • Standard, relay, fault isolator, and audible mounting bases

 

 

Additional information

Weight 1 lbs
Dimensions 5 × 5 × 5 in
Brand

Reviews

There are no reviews yet.

Be the first to review “Edwards SIGA-PHCD Multi-Sensor Smoke and Heat”

Your email address will not be published. Required fields are marked *

Payment & Security

Your Payment information is processed securely. We do not store credit card details, nor have access to your credit card information.

CUSTOMER TESTIMONIALS

What Our Customers Say

Can't find it?

    Select at least 2 products
    to compare