Description
The Gamewell FCI SS-APT is a commercial multi-sensor smoke detector designed for compatible Gamewell FCI fire alarm systems. Specifically, it combines optical smoke detection with thermal sensing to provide dependable life-safety protection in commercial buildings. This product is intended exclusively for commercial fire alarm installations and is not surveillance equipment, communications equipment, consumer electronics, tracking equipment, or recording devices.
Built for long-term reliability, the SS-APT features intelligent multi-sensor technology, automatic sensitivity adjustment, dual LED status indication, and a modern low-profile design. In addition, its durable off-white housing complements commercial interiors while supporting dependable fire detection in changing environmental conditions.
Product Functions
The Gamewell FCI SS-APT supports commercial fire alarm systems by providing:
- Optical smoke detection
- Supplemental thermal sensing
- Automatic sensitivity adjustment
- Dual LED status indication
- Rotary decimal address configuration
- Continuous environmental monitoring
- Reliable operation with compatible Gamewell FCI fire alarm control equipment
- Support for routine inspection and preventive maintenance
Electrical & System Information
The SS-APT operates with compatible Gamewell FCI SmartScan fire alarm control panels using the manufacturer’s specified operating voltage and system requirements. Furthermore, the detector automatically adjusts its sensitivity based on environmental smoke and heat conditions to help improve detection performance.
Always verify compatibility with the intended fire alarm control panel before installation.
Features
Multi-Sensor Detection
The SS-APT combines optical smoke sensing with thermal sensing to improve fire detection across a wide variety of commercial applications. As a result, the detector responds more effectively to changing environmental conditions.
Automatic Sensitivity Adjustment
The detector automatically adjusts its operating sensitivity without manual programming. Consequently, it adapts to environmental changes while maintaining dependable detection performance.
Dual LED Status Indicator
Dual bi-color LEDs provide 360-degree visibility for quick detector identification. Therefore, technicians can easily verify detector status during inspections and maintenance.
Rotary Address Switches
Rotary decimal switches simplify detector addressing and allow fast installation without specialized programming equipment. In addition, device addresses can be viewed and changed directly on the detector.
Low-Profile Commercial Design
The compact low-profile housing provides an attractive appearance while supporting dependable operation in commercial environments.
Mounting & Design
The Gamewell FCI SS-APT features a durable off-white housing designed for commercial installations. Furthermore, the detector installs on compatible detector bases using a simple plug-in design, allowing convenient installation, replacement, and maintenance.
Its tamper-resistant construction and sealed sensing chamber help support reliable long-term operation.
Protection & Applications
The SS-APT is designed exclusively for commercial fire alarm systems requiring dependable smoke detection with supplemental thermal sensing.
Typical protection includes:
- Smoke detection
- Supplemental heat sensing
- Commercial fire alarm systems
- Building life-safety protection
- Early fire detection
- Occupant safety
Always install the detector according to local building codes, fire codes, NFPA requirements, and the manufacturer’s installation instructions.
Compatibility
The Gamewell FCI SS-APT is designed for use with compatible Gamewell FCI SmartScan fire alarm control panels and approved detector bases.
Before purchasing or installing this detector, verify compatibility with the intended fire alarm system and all applicable project requirements.
Technical Specifications
Manufacturer: Gamewell FCI
Model: SS-APT
Product Type: Commercial Multi-Sensor Smoke Detector
Detection Technology: Optical Smoke Detection with Thermal Sensing
Operating Voltage: 15–32 VDC
Standby Current: 250 µA @ 24 VDC (typical)
LED Current: 6.5 mA @ 24 VDC
Addressing Method: Rotary Decimal Switches (01–99)
Status Indicator: Dual Bi-Color LEDs (360° Visibility)
Communication Loop: Two-Wire SLC
Construction: Bayblend® Commercial Thermoplastic
Housing Color: Off-White
Mounting Bases: SS-B6, B501, B501BH/B501BHT, B224RB, B224BI (application dependent)
Operating Features: Automatic Sensitivity Adjustment, Tamper Resistance, Sealed Sensing Chamber
Listings: UL Listed, CSFM Approved, MEA Approved (verify approvals for your application)
Always verify technical specifications using the manufacturer’s official documentation before installation.
Applications
The Gamewell FCI SS-APT is commonly installed in compatible commercial fire alarm systems serving:
- Office Buildings
- Schools
- Universities
- Hospitals
- Healthcare Facilities
- Hotels
- Government Buildings
- Retail Stores
- Warehouses
- Industrial Facilities
- Commercial Buildings
Before installation, verify compliance with local codes, project specifications, and manufacturer recommendations to ensure proper system operation.





Reviews
There are no reviews yet.