Description
Gamewell-FCI ASD-PL3 Intelligent Addressable Photoelectric Detector Head – White
The Gamewell-FCI ASD-PL3 is an intelligent addressable photoelectric detector head from Honeywell Gamewell-FCI’s Velociti Series 3. This professional fire alarm component uses an advanced optical sensing chamber to monitor airborne smoke particles associated with combustion.
Furthermore, the ASD-PL3 features a bright white housing, rotary address switches, dual LED indicators, and digital communication for compatible fire alarm control panels. Its low-profile construction supports approved commercial and institutional installations.
The detector operates through the Velociti communication protocol and provides individual point identification for compatible fire alarm systems. Consequently, maintenance personnel can locate specific devices and investigate alarm conditions efficiently.
Advanced Photoelectric Sensing Technology
The Gamewell-FCI ASD-PL3 uses an optical sensing chamber to monitor smoke particles produced by different combustion sources.
When smoke enters the sensing chamber, it changes the distribution of light inside the detector. The photoelectric sensor identifies these changes and communicates detection information to the connected fire alarm control panel.
Additionally, the manufacturer redesigned the sensing chamber to meet more stringent smoke detection requirements.
The detector’s sensitivity can be configured through compatible control panel software. Therefore, qualified technicians can select approved sensitivity settings according to the installation environment.
However, the ASD-PL3 does not include the integrated 135°F thermal element found in the separate ASD-PTL3 model.
Key Features and Benefits
The Gamewell-FCI ASD-PL3 offers several features for compatible professional fire alarm systems:
- Intelligent addressable photoelectric smoke sensing.
- Velociti Series 3 communication protocol.
- Bright white, low-profile detector housing.
- Rotary decimal address switches for individual device identification.
- Address range from 01 through 159 on compatible systems.
- Dual LED indicators for visible operating status.
- Panel-controlled red, green, and amber LED indications.
- Programmable sensitivity through compatible control panel software.
- Built-in magnetic functional test capability.
- Optional RA100Z remote LED annunciator support.
- Low standby current for efficient addressable circuit operation.
- Operating voltage range of 15–32VDC.
- Compatible standard, sounder, relay, and isolator mounting bases.
- Plug-in construction for convenient detector head replacement.
- Manufacturer documentation identifies UL 268 Seventh Edition compliance.
Intelligent Velociti Communication
The Gamewell-FCI ASD-PL3 communicates with compatible control panels through the Velociti addressable protocol.
Its rotary decimal switches allow technicians to assign individual device addresses. Additionally, the connected fire alarm control panel identifies each detector and monitors its operating status.
This arrangement helps maintenance personnel investigate reported alarm and trouble conditions.
Furthermore, the Velociti communication system supports individual detector identification without requiring a separate address card.
The ASD-PL3 supports Velociti communication only. Therefore, buyers should not assume compatibility with systems that require CLIP communication.
Programmable Smoke Sensitivity
The Gamewell-FCI ASD-PL3 supports programmable smoke sensitivity through compatible fire alarm control panel software.
This capability allows qualified technicians to configure the detector according to approved environmental and fire alarm requirements.
Furthermore, the detector’s redesigned optical chamber supports smoke sensing across a range of combustion conditions.
However, the connected control panel determines which sensitivity and maintenance functions are available.
Consequently, installers must verify the exact panel model and supported programming options before installation.
Dual LED Status Indicators
The ASD-PL3 includes two LED indicators that provide local operating information.
The connected fire alarm control panel controls the LEDs and can display red, green, or amber illumination.
Additionally, the indicators support steady, blinking, or inactive states according to system programming.
The detector also supports an optional RA100Z remote LED annunciator.
Therefore, technicians can provide additional visual status indication when the approved installation requires it.
Electrical Specifications and Performance
The Gamewell-FCI ASD-PL3 operates within a voltage range of 15–32VDC.
At 24VDC, the manufacturer specifies an operating current of approximately 200 microamps during normal communication with green LED activity.
Additionally, the maximum alarm current reaches 2 mA at 24VDC with the red LED illuminated.
Under the specified amber LED condition, maximum current reaches approximately 4.5 mA at 24VDC.
These ratings support operation on compatible addressable signaling line circuits.
However, technicians must verify control panel compatibility, circuit capacity, and approved device configurations before installation.
Environmental Operating Requirements
The Gamewell-FCI ASD-PL3 supports operating temperatures from 32°F to 122°F (0°C to 50°C).
Additionally, the manufacturer specifies a relative humidity range of 10% to 93%, non-condensing.
The detector supports air velocities from 0 to 4,000 feet per minute.
Furthermore, the detector head weighs approximately 3.4 ounces (95 grams).
When installed in a B300-6 mounting base, the complete assembly measures approximately 2 inches high and 6.2 inches in diameter.
With a B501 mounting base, the assembly measures approximately 4.1 inches in diameter.
These specifications help qualified installers evaluate appropriate mounting locations.
Compatible Mounting Bases and Accessories
The Gamewell-FCI ASD-PL3 uses a plug-in design that supports installation with approved detector mounting bases.
Compatible mounting arrangements include:
- B501-WHITE: Standard 4-inch white mounting base.
- B300-6: Standard 6-inch flanged mounting base.
- B200S-WH: Compatible intelligent sounder base.
- B224BI-WH: Compatible isolator mounting base.
- B224RB-WH: Compatible relay mounting base.
- RA100Z: Optional remote LED annunciator.
Furthermore, the manufacturer offers additional mounting accessories for approved system configurations.
However, mounting bases, sounders, remote annunciators, and other accessories are separate unless the actual product package includes them.
Compatibility with Gamewell-FCI Fire Alarm Systems
The ASD-PL3 belongs to the Velociti Series 3 addressable detector family.
It supports compatible Gamewell-FCI fire alarm control panels using the Velociti protocol.
Examples include approved E3 Series, S3 Series, and GWF-7075 configurations, subject to manufacturer compatibility documentation.
However, not every Gamewell-FCI control panel supports every detector generation.
Therefore, technicians must verify the exact panel model, firmware, signaling line circuit, and approved detector list.
The ASD-PL3 should not be substituted for the ASD-PL3-IV or other protocol variants without confirming compatibility.
Commercial and Institutional Applications
The Gamewell-FCI ASD-PL3 supports professional fire alarm detection in compatible buildings.
Potential applications include:
- Commercial office buildings
- Educational facilities and universities
- Healthcare and institutional properties
- Hotels and hospitality buildings
- Retail and commercial properties
- Suitable industrial facilities
- Existing Gamewell-FCI Velociti fire alarm maintenance projects
Furthermore, its addressable communication supports individual device identification and efficient system maintenance.
However, qualified professionals must evaluate detector placement, environmental conditions, system programming, and applicable fire safety requirements.
Genuine Honeywell Gamewell-FCI Equipment
The Gamewell-FCI ASD-PL3 is a manufacturer-documented intelligent addressable photoelectric detector head.
Honeywell’s Velociti Series 3 documentation identifies the ASD-PL3 as the bright white photoelectric-only model with Velociti communication.
Additionally, the manufacturer documents compliance with UL 268 Seventh Edition for this detector family.
The 2019 federal recall involving certain Gamewell-FCI photoelectric sensors specifically identifies ivory -IV models operating in CLIP mode under defined conditions. The white ASD-PL3 is not named in that recall.
However, this distinction does not establish the recall-free status, certification markings, or operating condition of an individual unit.
Before purchasing, review the actual product photographs to confirm the complete model number, white finish, manufacturer labeling, manufacturing date, physical condition, and included accessories.
Finally, qualified fire alarm professionals should verify compatibility, inspect the detector head, and perform appropriate functional testing before placing the equipment into service.





Reviews