Silent Knight IDP-ION Intelligent Addressable Ionization Detector Head

The Silent Knight IDP-ION is an intelligent addressable ionization detector head designed for compatible Honeywell Silent Knight fire alarm systems. It uses a single-source, dual-chamber ionization sensing design to monitor airborne combustion particles and communicate detection information to a compatible fire alarm control panel.

Additionally, the detector features rotary addressing, programmable sensitivity, and continuous sensitivity monitoring. Furthermore, its low-profile housing, dual LED indicators, and plug-in construction support professional installation and maintenance.

Advanced Ionization Sensing Technology

The Silent Knight IDP-ION uses ionization technology to monitor airborne combustion particles.

Unlike optical detectors, ionization detectors evaluate changes in electrical current within a sensing chamber.

During normal operation, the detector maintains a monitored electrical condition inside its chamber. Meanwhile, its electronics evaluate changes caused by airborne combustion particles.

When combustion particles enter the chamber, they affect the ionization current.

As a result, the detector recognizes changes associated with a developing fire.

Therefore, the connected fire alarm control panel can evaluate the detector’s information and initiate the appropriate alarm response.

Single-Source Dual-Chamber Design

The IDP-ION incorporates a single-source, dual-chamber sensing arrangement.

Additionally, the manufacturer designed this configuration to respond to a range of fire conditions.

The sensing system monitors changes in ionization current rather than relying on optical light scattering.

Consequently, the detector provides a different sensing method from the IDP-PHOTO family.

Furthermore, the dual-chamber design supports the manufacturer’s intelligent detection system.

However, sensing technology alone does not determine suitability for every environment.

Therefore, installers must follow the approved fire alarm design and applicable detector selection requirements.

Intelligent Addressable Communication

The IDP-ION communicates through compatible Silent Knight addressable signaling circuits.

Unlike conventional detectors, it provides individual device identification to the connected fire alarm control panel.

Therefore, the system can identify the specific detector associated with an alarm or maintenance condition.

Additionally, the detector transmits sensing information through its integrated communication electronics.

As a result, qualified technicians can investigate individual detector conditions.

Furthermore, addressable communication supports selective maintenance and troubleshooting.

However, the detector requires compatible Silent Knight IFP Series control equipment.

Consequently, installers must confirm panel compatibility before installation.

Rotary Device Addressing

The Silent Knight IDP-ION includes rotary decimal address switches.

During installation, qualified technicians assign the detector’s individual address.

Additionally, the address switches allow technicians to configure the detector before installing it into its mounting base.

Therefore, the control panel can identify the detector’s programmed location.

Furthermore, individual device addressing simplifies inspection and troubleshooting.

However, the supported address range depends on the connected fire alarm control panel.

Consequently, technicians must follow the applicable IFP Series installation instructions.

Programmable Detector Sensitivity

The IDP-ION supports programmable sensitivity through compatible Silent Knight control panel software.

Specifically, the manufacturer identifies selectable ionization sensitivity settings in compatible panel documentation.

For example, some IFP Series manuals describe low, medium, and high sensitivity selections.

Additionally, these settings are expressed in ionization current measurements rather than optical obscuration percentages.

Therefore, technicians must use the correct sensitivity values for this detector type.

Furthermore, sensitivity programming supports approved applications with different environmental requirements.

However, settings must comply with the manufacturer’s instructions and applicable fire alarm standards.

Continuous Sensitivity Monitoring

The detector continuously communicates sensing information to compatible control equipment.

Over time, dust and airborne contaminants may affect the sensing chamber.

Therefore, the fire alarm system monitors changes in detector performance.

Additionally, the detector can transmit a maintenance signal when contamination reaches an unacceptable level.

As a result, technicians can identify devices requiring cleaning or further inspection.

Furthermore, individual device identification supports targeted maintenance.

However, sensitivity monitoring does not eliminate required testing and cleaning.

Automatic Drift Compensation

Compatible Silent Knight IFP Series systems provide automatic drift compensation for IDP detectors.

During normal operation, gradual environmental changes may affect detector sensitivity.

Therefore, the system compensates for certain changes within the supported operating range.

Additionally, compatible control panels provide sensitivity information for maintenance review.

As a result, technicians can identify detectors approaching their service limits.

However, drift compensation cannot correct every contamination or equipment problem.

Consequently, technicians must inspect and service detectors that report abnormal conditions.

Dual LED Status Indicators

The IDP-ION includes two LED indicators for local operating information.

Additionally, their arrangement provides visibility from multiple directions.

The connected fire alarm control panel controls the LED indications.

For example, compatible systems can command the LEDs to blink, latch on, or latch off.

As a result, technicians can recognize certain operating and alarm conditions.

However, exact LED behavior depends on the control panel and system programming.

Therefore, maintenance personnel should consult the applicable panel documentation.

Key Features

  • Honeywell Silent Knight IDP Series
  • Exact model IDP-ION
  • Intelligent addressable ionization detector head
  • Single-source, dual-chamber sensing technology
  • Integrated addressable communication electronics
  • Compatible Silent Knight IFP Series communication
  • Rotary decimal address switches
  • Individual device identification
  • Programmable ionization sensitivity
  • Continuous sensitivity monitoring
  • Automatic drift compensation through compatible control equipment
  • Maintenance condition reporting
  • Dual LED status indicators
  • Local magnetic functional testing
  • Low-profile plug-in construction
  • Age-resistant polymer housing
  • Electromagnetic interference resistance
  • Field-cleanable sensing chamber
  • Compatible standard mounting bases
  • Compatible relay and isolator bases
  • Compatible sounder base
  • Optional remote LED annunciator
  • Tamper-resistant mounting option
  • 15–32 VDC operating voltage
  • Low standby current
  • 32°F–120°F operating temperature
  • 10–93% relative humidity, non-condensing
  • 0–1,200 FPM air velocity rating
  • Professional installation and testing required

Magnetic Functional Testing

The detector supports magnetic functional testing.

First, qualified technicians position an approved test magnet at the designated location.

Next, the detector electronically simulates a sensing condition.

Additionally, the connected fire alarm control panel evaluates the test response.

As a result, technicians can verify important detector electronics and communication functions.

However, magnetic testing does not replace every required functional test.

Therefore, maintenance personnel must follow the manufacturer’s testing instructions.

Compatible Mounting Bases

The IDP-ION supports several compatible Silent Knight detector mounting bases.

For example, the B501 provides a compact mounting arrangement.

Meanwhile, the B210LP provides a larger low-profile mounting base.

Additionally, the B224RB offers an auxiliary relay base.

Furthermore, the B224BI provides an isolator base option.

The manufacturer also identifies the B200SR sounder base for approved applications.

However, each base must be compatible with the connected control panel.

Therefore, technicians must verify the exact mounting arrangement before installation.

Optional Remote LED Annunciation

The IDP-ION supports an optional remote LED annunciator.

Specifically, the manufacturer identifies the RA100Z accessory.

Additionally, this remote indicator can provide visual alarm information at an accessible location.

As a result, technicians can monitor detector status when the detector itself is difficult to view.

However, remote annunciation is not the same as remote functional testing.

Therefore, installers must select the appropriate accessory for the required application.

Low-Current Electrical Operation

The IDP-ION operates from 15 to 32 VDC through a compatible addressable signaling circuit.

Additionally, the manufacturer’s datasheet specifies 150 microamps at 24 VDC with communication inactive and the LED off.

Meanwhile, the datasheet specifies 200 microamps at 24 VDC with communication every five seconds and the LED enabled.

Furthermore, the installation manual specifies a maximum average standby current of 300 microamps at 24 VDC.

Therefore, technicians must select the appropriate documented value for their circuit calculations.

Additionally, maximum alarm current is 6.5 mA at 24 VDC with the LED illuminated.

Environmental Operating Requirements

The detector operates in ambient temperatures from 32°F to 120°F (0°C to 49°C).

Additionally, the manufacturer specifies relative humidity from 10% to 93%, non-condensing.

Furthermore, the detector supports air velocities from 0 to 1,200 feet per minute.

These ratings help determine suitable installation environments.

However, the IDP-ION is designed for approved open-area applications.

Therefore, technicians must not assume that it is suitable for every HVAC duct detection installation.

Low-Profile Detector Construction

The IDP-ION features a compact plug-in detector housing.

Additionally, its age-resistant polymer construction supports long-term installation in approved indoor environments.

The detector measures approximately 2.0 inches high in its documented mounting configuration.

Meanwhile, its diameter depends on the selected mounting base.

As a result, technicians can select a compatible mounting arrangement for the installation.

Furthermore, approved mounting bases provide optional tamper-resistant functionality.

However, the mounting base is a separate component unless specifically included.

Typical Applications

The Silent Knight IDP-ION supports compatible commercial and institutional fire alarm installations.

For example, existing applications may include offices, schools, hotels, healthcare facilities, warehouses, and retail properties.

Additionally, its intelligent communication supports individual device identification.

Furthermore, sensitivity monitoring helps maintenance personnel identify detectors requiring service.

However, ionization sensing is not appropriate for every installation environment.

Therefore, detector selection must follow the approved fire alarm system design.

Installation and Compatibility

Before installation, technicians should verify the fire alarm control panel, signaling circuit, and mounting base.

Next, they should configure the correct detector address using the rotary switches.

Additionally, installers must inspect the detector housing, sensing chamber, and electrical contacts.

Qualified fire alarm professionals should install the device according to Silent Knight instructions.

Afterward, they must verify communication, alarm response, and maintenance reporting.

Therefore, the detector should enter service only after the required testing is complete.

Maintenance and Replacement

Regular maintenance helps preserve dependable detector operation.

First, technicians should inspect the sensing chamber and protective screen for contamination.

Next, they should review sensitivity information through the compatible control panel.

Additionally, they should perform approved functional and smoke-entry tests.

However, technicians must follow the manufacturer’s cleaning instructions and must not alter the internal sensing source.

Consequently, a detector that fails testing after approved cleaning must be replaced.

Furthermore, replacement equipment must match the installed system’s compatibility requirements.

Ionization Detector Handling and Disposal

Ionization detectors may contain a small sealed radioactive source as part of their sensing technology.

Therefore, technicians should keep the detector intact and avoid tampering with the internal ionization source.

Additionally, sellers must verify applicable transportation, disposal, and marketplace requirements before shipping or reselling used units.

However, the available manufacturer documents do not establish the radioactive source activity for every individual IDP-ION unit.

Consequently, the actual product label and manufacturer guidance should determine handling requirements.

Conclusion

Overall, the Silent Knight IDP-ION provides intelligent ionization-based fire sensing for compatible Silent Knight IFP Series systems.

Additionally, its rotary addressing, programmable sensitivity, continuous monitoring, and dual LED indicators support professional maintenance.

Furthermore, its low-profile plug-in design provides flexibility with approved mounting bases.

Therefore, the IDP-ION remains a potential replacement component for compatible installations when its condition, system compatibility, safety markings, and applicable handling requirements have been verified.

IDP-ION Datasheet

Additional information

Weight 1 lbs
Dimensions 5 × 5 × 5 in
Brand

Reviews

There are no reviews yet.

Be the first to review “Honeywell Silent Knight IDP-ION Addressable Ionization Detector”

Your email address will not be published. Required fields are marked *

Payment & Security

Your Payment information is processed securely. We do not store credit card details, nor have access to your credit card information.

Honeywell Silent Knight IDP-ION Addressable Ionization Detector

SKU IDP-ION Category Brand:
Price:
$289.00
Shipping calculated at checkout | Purchase & earn 289 points!
Stock:
9+ units in stock - ready to ship.
Quantity:

FAST SHIPPING

Orders ship same day

HUGE INVENTORY

Thousands of parts in stock

TRUSTED BY CONTRACTORS

Reliable products & service

24/7 ORDERING

Order anytime, anywhere

Description

Silent Knight IDP-ION Intelligent Addressable Ionization Detector Head

The Silent Knight IDP-ION is an intelligent addressable ionization detector head designed for compatible Honeywell Silent Knight fire alarm systems. It uses a single-source, dual-chamber ionization sensing design to monitor airborne combustion particles and communicate detection information to a compatible fire alarm control panel.

Additionally, the detector features rotary addressing, programmable sensitivity, and continuous sensitivity monitoring. Furthermore, its low-profile housing, dual LED indicators, and plug-in construction support professional installation and maintenance.

Advanced Ionization Sensing Technology

The Silent Knight IDP-ION uses ionization technology to monitor airborne combustion particles.

Unlike optical detectors, ionization detectors evaluate changes in electrical current within a sensing chamber.

During normal operation, the detector maintains a monitored electrical condition inside its chamber. Meanwhile, its electronics evaluate changes caused by airborne combustion particles.

When combustion particles enter the chamber, they affect the ionization current.

As a result, the detector recognizes changes associated with a developing fire.

Therefore, the connected fire alarm control panel can evaluate the detector’s information and initiate the appropriate alarm response.

Single-Source Dual-Chamber Design

The IDP-ION incorporates a single-source, dual-chamber sensing arrangement.

Additionally, the manufacturer designed this configuration to respond to a range of fire conditions.

The sensing system monitors changes in ionization current rather than relying on optical light scattering.

Consequently, the detector provides a different sensing method from the IDP-PHOTO family.

Furthermore, the dual-chamber design supports the manufacturer’s intelligent detection system.

However, sensing technology alone does not determine suitability for every environment.

Therefore, installers must follow the approved fire alarm design and applicable detector selection requirements.

Intelligent Addressable Communication

The IDP-ION communicates through compatible Silent Knight addressable signaling circuits.

Unlike conventional detectors, it provides individual device identification to the connected fire alarm control panel.

Therefore, the system can identify the specific detector associated with an alarm or maintenance condition.

Additionally, the detector transmits sensing information through its integrated communication electronics.

As a result, qualified technicians can investigate individual detector conditions.

Furthermore, addressable communication supports selective maintenance and troubleshooting.

However, the detector requires compatible Silent Knight IFP Series control equipment.

Consequently, installers must confirm panel compatibility before installation.

Rotary Device Addressing

The Silent Knight IDP-ION includes rotary decimal address switches.

During installation, qualified technicians assign the detector’s individual address.

Additionally, the address switches allow technicians to configure the detector before installing it into its mounting base.

Therefore, the control panel can identify the detector’s programmed location.

Furthermore, individual device addressing simplifies inspection and troubleshooting.

However, the supported address range depends on the connected fire alarm control panel.

Consequently, technicians must follow the applicable IFP Series installation instructions.

Programmable Detector Sensitivity

The IDP-ION supports programmable sensitivity through compatible Silent Knight control panel software.

Specifically, the manufacturer identifies selectable ionization sensitivity settings in compatible panel documentation.

For example, some IFP Series manuals describe low, medium, and high sensitivity selections.

Additionally, these settings are expressed in ionization current measurements rather than optical obscuration percentages.

Therefore, technicians must use the correct sensitivity values for this detector type.

Furthermore, sensitivity programming supports approved applications with different environmental requirements.

However, settings must comply with the manufacturer’s instructions and applicable fire alarm standards.

Continuous Sensitivity Monitoring

The detector continuously communicates sensing information to compatible control equipment.

Over time, dust and airborne contaminants may affect the sensing chamber.

Therefore, the fire alarm system monitors changes in detector performance.

Additionally, the detector can transmit a maintenance signal when contamination reaches an unacceptable level.

As a result, technicians can identify devices requiring cleaning or further inspection.

Furthermore, individual device identification supports targeted maintenance.

However, sensitivity monitoring does not eliminate required testing and cleaning.

Automatic Drift Compensation

Compatible Silent Knight IFP Series systems provide automatic drift compensation for IDP detectors.

During normal operation, gradual environmental changes may affect detector sensitivity.

Therefore, the system compensates for certain changes within the supported operating range.

Additionally, compatible control panels provide sensitivity information for maintenance review.

As a result, technicians can identify detectors approaching their service limits.

However, drift compensation cannot correct every contamination or equipment problem.

Consequently, technicians must inspect and service detectors that report abnormal conditions.

Dual LED Status Indicators

The IDP-ION includes two LED indicators for local operating information.

Additionally, their arrangement provides visibility from multiple directions.

The connected fire alarm control panel controls the LED indications.

For example, compatible systems can command the LEDs to blink, latch on, or latch off.

As a result, technicians can recognize certain operating and alarm conditions.

However, exact LED behavior depends on the control panel and system programming.

Therefore, maintenance personnel should consult the applicable panel documentation.

Key Features

  • Honeywell Silent Knight IDP Series
  • Exact model IDP-ION
  • Intelligent addressable ionization detector head
  • Single-source, dual-chamber sensing technology
  • Integrated addressable communication electronics
  • Compatible Silent Knight IFP Series communication
  • Rotary decimal address switches
  • Individual device identification
  • Programmable ionization sensitivity
  • Continuous sensitivity monitoring
  • Automatic drift compensation through compatible control equipment
  • Maintenance condition reporting
  • Dual LED status indicators
  • Local magnetic functional testing
  • Low-profile plug-in construction
  • Age-resistant polymer housing
  • Electromagnetic interference resistance
  • Field-cleanable sensing chamber
  • Compatible standard mounting bases
  • Compatible relay and isolator bases
  • Compatible sounder base
  • Optional remote LED annunciator
  • Tamper-resistant mounting option
  • 15–32 VDC operating voltage
  • Low standby current
  • 32°F–120°F operating temperature
  • 10–93% relative humidity, non-condensing
  • 0–1,200 FPM air velocity rating
  • Professional installation and testing required

Magnetic Functional Testing

The detector supports magnetic functional testing.

First, qualified technicians position an approved test magnet at the designated location.

Next, the detector electronically simulates a sensing condition.

Additionally, the connected fire alarm control panel evaluates the test response.

As a result, technicians can verify important detector electronics and communication functions.

However, magnetic testing does not replace every required functional test.

Therefore, maintenance personnel must follow the manufacturer’s testing instructions.

Compatible Mounting Bases

The IDP-ION supports several compatible Silent Knight detector mounting bases.

For example, the B501 provides a compact mounting arrangement.

Meanwhile, the B210LP provides a larger low-profile mounting base.

Additionally, the B224RB offers an auxiliary relay base.

Furthermore, the B224BI provides an isolator base option.

The manufacturer also identifies the B200SR sounder base for approved applications.

However, each base must be compatible with the connected control panel.

Therefore, technicians must verify the exact mounting arrangement before installation.

Optional Remote LED Annunciation

The IDP-ION supports an optional remote LED annunciator.

Specifically, the manufacturer identifies the RA100Z accessory.

Additionally, this remote indicator can provide visual alarm information at an accessible location.

As a result, technicians can monitor detector status when the detector itself is difficult to view.

However, remote annunciation is not the same as remote functional testing.

Therefore, installers must select the appropriate accessory for the required application.

Low-Current Electrical Operation

The IDP-ION operates from 15 to 32 VDC through a compatible addressable signaling circuit.

Additionally, the manufacturer’s datasheet specifies 150 microamps at 24 VDC with communication inactive and the LED off.

Meanwhile, the datasheet specifies 200 microamps at 24 VDC with communication every five seconds and the LED enabled.

Furthermore, the installation manual specifies a maximum average standby current of 300 microamps at 24 VDC.

Therefore, technicians must select the appropriate documented value for their circuit calculations.

Additionally, maximum alarm current is 6.5 mA at 24 VDC with the LED illuminated.

Environmental Operating Requirements

The detector operates in ambient temperatures from 32°F to 120°F (0°C to 49°C).

Additionally, the manufacturer specifies relative humidity from 10% to 93%, non-condensing.

Furthermore, the detector supports air velocities from 0 to 1,200 feet per minute.

These ratings help determine suitable installation environments.

However, the IDP-ION is designed for approved open-area applications.

Therefore, technicians must not assume that it is suitable for every HVAC duct detection installation.

Low-Profile Detector Construction

The IDP-ION features a compact plug-in detector housing.

Additionally, its age-resistant polymer construction supports long-term installation in approved indoor environments.

The detector measures approximately 2.0 inches high in its documented mounting configuration.

Meanwhile, its diameter depends on the selected mounting base.

As a result, technicians can select a compatible mounting arrangement for the installation.

Furthermore, approved mounting bases provide optional tamper-resistant functionality.

However, the mounting base is a separate component unless specifically included.

Typical Applications

The Silent Knight IDP-ION supports compatible commercial and institutional fire alarm installations.

For example, existing applications may include offices, schools, hotels, healthcare facilities, warehouses, and retail properties.

Additionally, its intelligent communication supports individual device identification.

Furthermore, sensitivity monitoring helps maintenance personnel identify detectors requiring service.

However, ionization sensing is not appropriate for every installation environment.

Therefore, detector selection must follow the approved fire alarm system design.

Installation and Compatibility

Before installation, technicians should verify the fire alarm control panel, signaling circuit, and mounting base.

Next, they should configure the correct detector address using the rotary switches.

Additionally, installers must inspect the detector housing, sensing chamber, and electrical contacts.

Qualified fire alarm professionals should install the device according to Silent Knight instructions.

Afterward, they must verify communication, alarm response, and maintenance reporting.

Therefore, the detector should enter service only after the required testing is complete.

Maintenance and Replacement

Regular maintenance helps preserve dependable detector operation.

First, technicians should inspect the sensing chamber and protective screen for contamination.

Next, they should review sensitivity information through the compatible control panel.

Additionally, they should perform approved functional and smoke-entry tests.

However, technicians must follow the manufacturer’s cleaning instructions and must not alter the internal sensing source.

Consequently, a detector that fails testing after approved cleaning must be replaced.

Furthermore, replacement equipment must match the installed system’s compatibility requirements.

Ionization Detector Handling and Disposal

Ionization detectors may contain a small sealed radioactive source as part of their sensing technology.

Therefore, technicians should keep the detector intact and avoid tampering with the internal ionization source.

Additionally, sellers must verify applicable transportation, disposal, and marketplace requirements before shipping or reselling used units.

However, the available manufacturer documents do not establish the radioactive source activity for every individual IDP-ION unit.

Consequently, the actual product label and manufacturer guidance should determine handling requirements.

Conclusion

Overall, the Silent Knight IDP-ION provides intelligent ionization-based fire sensing for compatible Silent Knight IFP Series systems.

Additionally, its rotary addressing, programmable sensitivity, continuous monitoring, and dual LED indicators support professional maintenance.

Furthermore, its low-profile plug-in design provides flexibility with approved mounting bases.

Therefore, the IDP-ION remains a potential replacement component for compatible installations when its condition, system compatibility, safety markings, and applicable handling requirements have been verified.

IDP-ION Datasheet

Additional information

Weight 1 lbs
Dimensions 5 × 5 × 5 in
Brand

Reviews

There are no reviews yet.

Be the first to review “Honeywell Silent Knight IDP-ION Addressable Ionization Detector”

Your email address will not be published. Required fields are marked *

Payment & Security

Your Payment information is processed securely. We do not store credit card details, nor have access to your credit card information.

CUSTOMER TESTIMONIALS

What Our Customers Say

Select at least 2 products
to compare