Description
The Vigilant GSA-CT2 is a commercial dual input module designed for compatible Vigilant Signature Series fire alarm systems. It connects one or two normally open dry-contact initiating device circuits to a Signature Loop Controller, allowing conventional alarm, supervisory, waterflow, and monitoring devices to report individually through the addressable fire alarm system.
Each input channel can be programmed independently using one of four personality codes. This allows the module to monitor different device types from the same installation, such as a waterflow switch on one circuit and a valve tamper switch on the second circuit. This product is intended exclusively for commercial fire alarm installations.
Product Functions
- Monitors up to two normally open dry-contact circuits
- Provides two supervised Class B initiating device circuits
- Supports alarm device monitoring
- Supports delayed waterflow alarm monitoring
- Supports supervisory device monitoring
- Supports non-latching equipment status monitoring
- Reports each input through a separate module address
- Provides continuous Signature loop communication
- Detects ground faults at the device level
Electrical & System Information
The GSA-CT2 operates from the compatible Signature Data Circuit at 15.2–19.95 VDC and uses two module addresses, one for each input channel. Electronic addressing is assigned through the Signature Loop Controller, compatible programming software, or a Signature service tool, eliminating mechanical address switches or rotary dials.
Each input is supervised with a 47 kΩ end-of-line resistor and supports normally open dry-contact initiating devices. The two channels can use different personality codes, allowing separate alarm, delayed alarm, supervisory, or monitor functions within the same module.
Features
- Commercial dual input module
- Two Class B dry-contact input circuits
- Electronic addressing
- Uses two Signature module addresses
- Four selectable personality codes
- Automatic device mapping
- Stand-alone alarm decision capability
- Ground-fault detection by address
- Onboard microprocessor
- Self-diagnostics and history logging
- Green polling LED
- Red alarm and active LED
- High-impact polymer enclosure
- Compact one-gang design
Mounting & Design
The GSA-CT2 mounts in a standard North American 2½-inch-deep single-gang electrical box or a 1½-inch-deep 4-inch square box equipped with a single-gang cover and compatible mounting plate.
The module includes removable terminal connections suitable for 12–18 AWG conductors. Its compact wall-plate design makes it suitable for remote locations where a single dual-input module is required.
Protection & Applications
Suitable for:
- Manual Pull Stations
- Waterflow Alarm Switches
- Valve Tamper Switches
- Conventional Heat Detectors
- Fan Status Contacts
- Damper Position Contacts
- Door Position Contacts
- Pressure Switches
- Commercial Fire Alarm Systems
Compatibility
Compatible with:
- Vigilant Signature Series Fire Alarm Systems
- Vigilant Signature Loop Controllers
- Signature Data Circuits
- Normally Open Dry-Contact Alarm Devices
- Normally Open Supervisory Devices
- Normally Open Monitor Contacts
- GSA-MP Series Mounting Plates
- Compatible Single-Gang Surface Boxes
Always verify compatibility with the installed Vigilant fire alarm control panel, Signature Loop Controller, firmware version, assigned personality codes, and connected initiating devices before installation. The module does not support conventional two-wire smoke detectors.
Technical Specifications
Manufacturer: Vigilant
Brand Family: Edwards / Kidde Commercial
Model: GSA-CT2
Product Type: Dual Input Module
Input Circuits: Two Supervised Class B IDCs
Supported Contacts: Normally Open Dry Contacts
Applications: Alarm, Delayed Alarm, Supervisory, and Monitor
Personality Codes: Four Selectable Types
Address Requirements: Two Module Addresses
Addressing: Electronic
Operating Voltage: 15.2–19.95 VDC
Nominal Operating Voltage: 19 VDC
Standby Current: 396 µA
Activated Current: 680 µA
End-of-Line Resistor: 47 kΩ
Status Indicators: Green Polling LED and Red Alarm/Active LED
Wire Size: 12–18 AWG
Operating Temperature: 32°F to 120°F (0°C to 49°C)
Storage Temperature: –4°F to 140°F (–20°C to 60°C)
Operating Humidity: 0%–93% RH Non-Condensing
Construction: High-Impact Engineering Polymer
Mounting: Single-Gang or 4-Inch Square Electrical Box
Shipping Weight: 0.4 lb. (0.15 kg)
Application: Indoor Commercial Fire Alarm Systems
Listings: UL Listed, ULC Listed, CSFM Listed, and MEA Approved as applicable. Verify the product label and project requirements before installation.
Applications
The Vigilant GSA-CT2 is designed for commercial fire alarm systems requiring independent monitoring of two conventional dry-contact devices from one compact module. Typical applications include monitoring manual pull stations, sprinkler waterflow switches, valve tamper switches, conventional heat detectors, pressure switches, fan status contacts, smoke damper position contacts, and other normally open initiating devices in schools, hospitals, offices, warehouses, industrial facilities, and commercial buildings.





Reviews
There are no reviews yet.