Description
The Edwards SIGA-MAB Intelligent Addressable Input/Output Module is a Signature Series Universal Class A/B Module designed for flexible fire alarm interface applications. Its function is determined by a downloadable personality code, allowing the module to operate with initiating device circuits, compatible two-wire smoke detector circuits, or notification appliance circuits.
The SIGA-MAB is the UIO motherboard-mounted version of the Edwards universal Class A/B module. It plugs into compatible two- or six-position UIO motherboards, while field wiring terminates on the motherboard terminal blocks.
Product Functions
- Intelligent addressable input/output module
- Supports Class A initiating device circuits
- Supports Class B initiating device circuits
- Supports Class A two-wire smoke detector circuits
- Supports Class B two-wire smoke detector circuits
- Supports Class A notification appliance circuits
- Supports Class B notification appliance circuits
- Supports dry-contact initiating devices
- Supports compatible conventional two-wire smoke detectors
- Supports 24 VDC notification circuits
- Supports 25 V audio circuits
- Supports 70 V audio circuits
- Uses downloadable personality codes
- Provides automatic device mapping
- Uses electronic addressing
- Provides onboard status LEDs
- Mounts on compatible UIO motherboards
- Integrates with Edwards Signature Series loop controllers
Initiating Device Circuit
The SIGA-MAB can monitor conventional dry-contact initiating devices such as:
- Manual pull stations
- Heat detectors
- Waterflow switches
- Supervisory switches
- Other compatible normally open contacts
For Class B dry-contact applications, Edwards documentation identifies personality codes 1, 2, 3, and 4. Class A equivalents use personality codes 9, 10, 11, and 12.
Personality Code 2 provides delayed latching operation, requiring the input contact to remain closed for approximately 16 seconds before an alarm is generated, making it suitable for appropriate waterflow applications.
Two-Wire Smoke Detector Circuits
The SIGA-MAB can interface compatible conventional two-wire smoke detectors with an Edwards Signature Series system.
Published configurations include:
Class B Smoke Input: Personality Codes 13 and 14
Class A Smoke Input: Personality Codes 20 and 21.
Only smoke detectors specifically approved for use with the applicable Edwards control system should be connected.
Notification Appliance Circuit
The SIGA-MAB can also function as a notification output module.
Published configurations include:
Personality Code 15: Class A NAC
Personality Code 16: Class B NAC.
This allows compatible externally powered horns, strobes, or audio circuits to be controlled through the addressable Signature system.
Output Ratings
Published SIGA-MAB output ratings are:
24 VDC: 2 A
25 V Audio: 50 W
70 V Audio: 35 W.
Edwards identifies the applicable circuits as power-limited.
Personality Codes
The SIGA-MAB supports:
14 selectable personality codes.
These personality codes determine whether the module operates as:
- Class A dry-contact input
- Class B dry-contact input
- Delayed alarm input
- Supervisory input
- Class A two-wire smoke input
- Class B two-wire smoke input
- Class A notification output
- Class B notification output
The personality code is downloaded from the Signature loop controller during system configuration.
Electronic Addressing
The SIGA-MAB uses electronic addressing rather than DIP switches or rotary dials.
Programmable addresses can be downloaded from the loop controller, a PC, or compatible Signature programming/service equipment.
Published Edwards specifications identify the SIGA-MAB as requiring:
Two module addresses.
Automatic Device Mapping
The SIGA-MAB supports Edwards automatic device mapping.
Signature modules transmit information to the loop controller describing their physical location relative to other Signature devices on the loop. This assists with system configuration, commissioning, and troubleshooting.
LED Indicators
The SIGA-MAB includes onboard diagnostic LEDs:
Green LED: Flashes when the module is polled
Red LED: Flashes when the module is in alarm or active.
These indicators provide technicians with immediate visual confirmation of communication and module status.
UIO Motherboard Mounting
The SIGA-MAB is specifically designed as a plug-in UIO module.
Compatible Edwards motherboards include:
UIO2R
UIO6R
UIO6.
The module plugs into an available motherboard position and is secured to the board. All field wiring connections are made to motherboard terminals.
Wiring Specifications
Supported Wire Size: #12–18 AWG
Metric Range: approximately 2.5–0.75 mm².
Field wiring is terminated at the associated UIO motherboard rather than directly on the plug-in SIGA-MAB module.
Construction
Construction: High-impact engineering polymer.
The compact module is designed for protected installation inside a compatible Edwards UIO enclosure.
Environmental Specifications
Operating Temperature: 32°F to 120°F / 0°C to 49°C
Storage Temperature: −4°F to 140°F / −20°C to 60°C
Relative Humidity: 0–93% RH.
Installation Information
Typical SIGA-MAB installation includes:
- Installing a compatible UIO motherboard
- Mounting the motherboard in an Edwards enclosure
- Plugging the SIGA-MAB into an available position
- Securing the module
- Connecting Signature loop wiring
- Connecting the required IDC, smoke detector, or notification circuit
- Installing the appropriate EOL resistor where required
- Selecting the correct personality code
- Programming the module
- Confirming electronic addressing
- Restoring system operation
- Testing input/output functionality
- Verifying circuit supervision
- Confirming normal fire alarm panel status
The dedicated installation sheet is P/N 387356P.
Testing & Maintenance
Inspection should verify:
- Module is securely seated
- Motherboard connections are secure
- Correct personality code is programmed
- Correct Class A/B configuration is used
- Correct EOL resistor is installed where required
- Green polling LED operates
- Red active LED operates
- Initiating inputs respond properly
- Smoke detector circuits operate correctly
- Notification outputs activate correctly
- Open-circuit supervision operates properly
- System returns to normal after testing
Product Identification
- Manufacturer: Edwards
- Brand: Edwards / EST
- Model: SIGA-MAB
- Product Name: Intelligent Addressable Input/Output Module
- Product Family: Signature Series
- Product Type: Universal Class A/B Input/Output Module
- Mounting: UIO motherboard
- Class A IDC: Supported
- Class B IDC: Supported
- Class A Two-Wire Smoke: Supported
- Class B Two-Wire Smoke: Supported
- Class A NAC: Supported
- Class B NAC: Supported
- 24 VDC Output: 2 A
- 25 V Audio: 50 W
- 70 V Audio: 35 W
- Operating Voltage: 15.2–19.95 VDC
- Personality Codes: 14 selectable
- Address Requirement: Two module addresses
- Wire Range: #12–18 AWG
- Operating Temperature: 0°C–49°C
- Humidity: 0–93% RH
- Construction: High-impact engineering polymer
- Shipping Weight: approximately 0.10 lb / 0.05 kg
- Compatible Motherboards: UIO2R / UIO6R / UIO6
- Listings: UL / ULC / MEA / CSFM
Applications
Suitable for:
- Edwards Signature Series Systems
- Intelligent Addressable Fire Alarm Systems
- EST3 Systems
- EST4 Applications
- Initiating Device Circuits
- Manual Pull Stations
- Heat Detectors
- Waterflow Monitoring
- Supervisory Monitoring
- Conventional Two-Wire Smoke Detectors
- Notification Appliance Circuits
- Horn and Strobe Circuits
- 25V Speaker Circuits
- 70V Speaker Circuits
- Commercial Buildings
- Hospitals
- Schools
- Hotels
- High-Rise Buildings
- Government Facilities
- Industrial Facilities
The Edwards SIGA-MAB Intelligent Addressable Input/Output Module provides a flexible interface between Signature Series addressable systems and conventional initiating, smoke detection, notification, or audio circuits. Its programmable Class A/B operation and UIO plug-in design make it particularly useful for centralized fire alarm interface applications.




Reviews
There are no reviews yet.