Description

The Fire-Lite MMF-301 is an addressable mini monitor module designed for compatible Fire-Lite intelligent fire alarm control panels. It provides an addressable interface for monitoring normally open dry-contact initiating devices, allowing conventional initiating devices to communicate with the fire alarm control panel over the Signaling Line Circuit (SLC).

Its miniature design allows installation inside a standard single-gang electrical box directly behind the monitored device, making it an excellent solution for retrofit applications and locations with limited installation space. This product is intended exclusively for commercial fire alarm installations.


Product Functions

  • Monitors normally open dry-contact initiating devices
  • Provides a supervised Class B (Style B) initiating device circuit
  • Reports alarm and supervisory conditions to the fire alarm control panel
  • Supervises initiating device wiring
  • Supports individual address identification
  • Monitors manual pull stations, waterflow switches, tamper switches, pressure switches, and similar dry-contact devices
  • Continuous communication with the Signaling Line Circuit (SLC)

Electrical & System Information

The MMF-301 operates directly from the compatible Fire-Lite 15–32 VDC Signaling Line Circuit (SLC) and requires no separate operating power supply. Rotary decimal switches provide simple field addressing.

The initiating device circuit is supervised using the supplied 47 kΩ end-of-line resistor and supports up to 1,500 Ω of wiring resistance. The module is intended for concealed installation without rigid mounting inside a standard single-gang electrical box.


Features

  • Commercial addressable mini monitor module
  • Compact concealed design
  • Class B (Style B) initiating device circuit
  • Powered directly from the SLC
  • Rotary decimal addressing
  • High EMI/RFI immunity
  • Factory-installed tinned wire leads
  • 47 kΩ end-of-line resistor included
  • Lightweight construction
  • Ideal for retrofit applications

Mounting & Design

The MMF-301 is designed to fit inside a standard single-gang electrical box located behind the monitored device. Its compact dimensions allow installation where conventional monitor modules may not fit.

The module includes factory-installed wire leads to simplify wiring and eliminate the need for rigid mounting hardware, making installation faster while maintaining reliable system supervision.


Protection & Applications

Suitable for monitoring:

  • Manual Pull Stations
  • Waterflow Switches
  • Valve Tamper Switches
  • Fire Pump Supervisory Switches
  • Pressure Switches
  • Security Dry-Contact Devices
  • Conventional Heat Detectors
  • Commercial Fire Alarm Systems

Compatibility

Compatible with:

  • Fire-Lite Addressable Fire Alarm Control Panels
  • LiteSpeed® Signaling Line Circuits
  • CLIP Signaling Line Circuits
  • ES-50X Fire Alarm Control Panel
  • ES-200X Fire Alarm Control Panel
  • MS-9050UD Fire Alarm Control Panel
  • MS-9200UDLS Fire Alarm Control Panel
  • MS-9600UDLS Fire Alarm Control Panel
  • Normally Open Dry-Contact Devices

Always verify compatibility with the installed Fire-Lite fire alarm control panel, SLC protocol, firmware version, and monitored initiating device before installation. The MMF-301 is functionally equivalent to the MMF-300 but is housed in a smaller enclosure for concealed installations.


Technical Specifications

Manufacturer: Fire-Lite
Parent Company: Honeywell
Model: MMF-301
Product Type: Addressable Mini Monitor Module
Circuit Type: Class B (Style B) Initiating Device Circuit
Operating Voltage: 15–32 VDC
Power Source: Signaling Line Circuit (SLC)
Average Operating Current: 350 µA (Direct Poll)
Average Operating Current: 375 µA (Group Poll)
Maximum Operating Current: 600 µA
End-of-Line Resistor: 47 kΩ (Included)
Maximum IDC Wiring Resistance: 1,500 Ω
Maximum IDC Voltage: 11 VDC
Maximum IDC Current: 450 µA
Addressing: Rotary Decimal Switches
Address Range: 01–159 (Panel Dependent)
Operating Temperature: 32°F to 120°F (0°C to 49°C)
Operating Humidity: 10%–93% RH Non-Condensing
Dimensions: 2.75 × 1.30 × 0.65 in. (69.9 × 33 × 16.5 mm)
Wire Lead Length: 6 in. Minimum
Mounting: Standard Single-Gang Electrical Box
Application: Indoor Commercial Fire Alarm Systems
Product Status: Discontinued
Listings: UL Listed, FM Approved, and CSFM Listed (application dependent)


Applications

The Fire-Lite MMF-301 is designed for commercial fire alarm systems requiring addressable monitoring of conventional dry-contact initiating devices. Typical applications include manual pull stations, sprinkler waterflow switches, valve tamper switches, fire pump supervisory switches, pressure switches, conventional heat detectors, and other normally open contact devices installed in offices, schools, hospitals, warehouses, industrial facilities, and other commercial occupancies.

MMF-301

Additional information

Weight 2 lbs
Dimensions 5 × 5 × 5 in

Reviews

There are no reviews yet.

Be the first to review “Fire-Lite MMF-301 Addressable Mini Monitor Module”

Your email address will not be published. Required fields are marked *

Payment & Security

Your Payment information is processed securely. We do not store credit card details, nor have access to your credit card information.

Fire-Lite MMF-301 Addressable Mini Monitor Module

SKU MMF-301 Category Brand:
Price:
$51.00
Shipping calculated at checkout | Purchase & earn 51 points!
Stock:
2075+ units in stock - ready to ship.
Quantity:

FAST SHIPPING

Orders ship same day

HUGE INVENTORY

Thousands of parts in stock

TRUSTED BY CONTRACTORS

Reliable products & service

24/7 ORDERING

Order anytime, anywhere

Description

The Fire-Lite MMF-301 is an addressable mini monitor module designed for compatible Fire-Lite intelligent fire alarm control panels. It provides an addressable interface for monitoring normally open dry-contact initiating devices, allowing conventional initiating devices to communicate with the fire alarm control panel over the Signaling Line Circuit (SLC).

Its miniature design allows installation inside a standard single-gang electrical box directly behind the monitored device, making it an excellent solution for retrofit applications and locations with limited installation space. This product is intended exclusively for commercial fire alarm installations.


Product Functions

  • Monitors normally open dry-contact initiating devices
  • Provides a supervised Class B (Style B) initiating device circuit
  • Reports alarm and supervisory conditions to the fire alarm control panel
  • Supervises initiating device wiring
  • Supports individual address identification
  • Monitors manual pull stations, waterflow switches, tamper switches, pressure switches, and similar dry-contact devices
  • Continuous communication with the Signaling Line Circuit (SLC)

Electrical & System Information

The MMF-301 operates directly from the compatible Fire-Lite 15–32 VDC Signaling Line Circuit (SLC) and requires no separate operating power supply. Rotary decimal switches provide simple field addressing.

The initiating device circuit is supervised using the supplied 47 kΩ end-of-line resistor and supports up to 1,500 Ω of wiring resistance. The module is intended for concealed installation without rigid mounting inside a standard single-gang electrical box.


Features

  • Commercial addressable mini monitor module
  • Compact concealed design
  • Class B (Style B) initiating device circuit
  • Powered directly from the SLC
  • Rotary decimal addressing
  • High EMI/RFI immunity
  • Factory-installed tinned wire leads
  • 47 kΩ end-of-line resistor included
  • Lightweight construction
  • Ideal for retrofit applications

Mounting & Design

The MMF-301 is designed to fit inside a standard single-gang electrical box located behind the monitored device. Its compact dimensions allow installation where conventional monitor modules may not fit.

The module includes factory-installed wire leads to simplify wiring and eliminate the need for rigid mounting hardware, making installation faster while maintaining reliable system supervision.


Protection & Applications

Suitable for monitoring:

  • Manual Pull Stations
  • Waterflow Switches
  • Valve Tamper Switches
  • Fire Pump Supervisory Switches
  • Pressure Switches
  • Security Dry-Contact Devices
  • Conventional Heat Detectors
  • Commercial Fire Alarm Systems

Compatibility

Compatible with:

  • Fire-Lite Addressable Fire Alarm Control Panels
  • LiteSpeed® Signaling Line Circuits
  • CLIP Signaling Line Circuits
  • ES-50X Fire Alarm Control Panel
  • ES-200X Fire Alarm Control Panel
  • MS-9050UD Fire Alarm Control Panel
  • MS-9200UDLS Fire Alarm Control Panel
  • MS-9600UDLS Fire Alarm Control Panel
  • Normally Open Dry-Contact Devices

Always verify compatibility with the installed Fire-Lite fire alarm control panel, SLC protocol, firmware version, and monitored initiating device before installation. The MMF-301 is functionally equivalent to the MMF-300 but is housed in a smaller enclosure for concealed installations.


Technical Specifications

Manufacturer: Fire-Lite
Parent Company: Honeywell
Model: MMF-301
Product Type: Addressable Mini Monitor Module
Circuit Type: Class B (Style B) Initiating Device Circuit
Operating Voltage: 15–32 VDC
Power Source: Signaling Line Circuit (SLC)
Average Operating Current: 350 µA (Direct Poll)
Average Operating Current: 375 µA (Group Poll)
Maximum Operating Current: 600 µA
End-of-Line Resistor: 47 kΩ (Included)
Maximum IDC Wiring Resistance: 1,500 Ω
Maximum IDC Voltage: 11 VDC
Maximum IDC Current: 450 µA
Addressing: Rotary Decimal Switches
Address Range: 01–159 (Panel Dependent)
Operating Temperature: 32°F to 120°F (0°C to 49°C)
Operating Humidity: 10%–93% RH Non-Condensing
Dimensions: 2.75 × 1.30 × 0.65 in. (69.9 × 33 × 16.5 mm)
Wire Lead Length: 6 in. Minimum
Mounting: Standard Single-Gang Electrical Box
Application: Indoor Commercial Fire Alarm Systems
Product Status: Discontinued
Listings: UL Listed, FM Approved, and CSFM Listed (application dependent)


Applications

The Fire-Lite MMF-301 is designed for commercial fire alarm systems requiring addressable monitoring of conventional dry-contact initiating devices. Typical applications include manual pull stations, sprinkler waterflow switches, valve tamper switches, fire pump supervisory switches, pressure switches, conventional heat detectors, and other normally open contact devices installed in offices, schools, hospitals, warehouses, industrial facilities, and other commercial occupancies.

MMF-301

Additional information

Weight 2 lbs
Dimensions 5 × 5 × 5 in

Reviews

There are no reviews yet.

Be the first to review “Fire-Lite MMF-301 Addressable Mini Monitor Module”

Your email address will not be published. Required fields are marked *

Payment & Security

Your Payment information is processed securely. We do not store credit card details, nor have access to your credit card information.

CUSTOMER TESTIMONIALS

What Our Customers Say

Related Products

Select at least 2 products
to compare