Honeywell ASD-PL3-BP

Models ASD-PL3 and ASD-PL3-IV are plug-in-type smoke sensors that combine a photoelectronic sensing chamber with addressable-analog communications.
The sensors transmit an analog representation of smoke density over a communication line to a control panel. Rotary dial switches are provided for setting the sensor’s address.

Two LEDs on the sensor a r e controlled by the panel to indicate sensor status.
An output is provided for connection to an optional remote LED annunciator (P/N RA100Z).
Gamewell-FCI panels offer different feature sets across different models. Certain features of the photoelectric sensors may – available on some control panels. ASD-PL3 will support only Velociti® Series protocol mode. ASD-PL3-IV will support  Velociti or CLIP (Classic Loop Interface Protocol) mode. The possible features available if supported by the control panel are:
1. The sensor’s LEDs can operate in three ways—on, off, and blinking. And they can – set to red, green, or amber. This – controlled by the panel.
2. The remote output may – synchronized to the LED operation or controlled independently of the LEDs.
3. Devices are point addressable up to 159 addresses.
Please refer to the operation manual for the UL-listed control panel for specific operations. The photoelectric sensors require compatible addressable communications to function properly. Connect these sensors to listed-compatible control panels only.

Honeywell ASD-PL3-BP

All wiring must – installed in compliance with the National Electrical Code, and applicable local codes. And any special requirements of the Authority Having Jurisdiction. Proper wire gauges should – used. The installation wires should – color-coded to limit wiring mistakes and ease system troubleshooting. Improper connections will prevent a system from responding properly in the event of a fire.

Datasheet

Relative Item

Additional information

Weight 4 lbs
Dimensions 16 × 7 × 7 in

Reviews

There are no reviews yet.

Be the first to review “Honeywell ASD-PL3-BP Smoke Detector”

Your email address will not be published. Required fields are marked *

Payment & Security

Your Payment information is processed securely. We do not store credit card details, nor have access to your credit card information.

Honeywell ASD-PL3-BP Smoke Detector

SKU ASD-PL3-BP Category Tag Brand:
Price:
Original price was: $669.00.Current price is: $600.00.
Shipping calculated at checkout | Purchase & earn 600 points!
Stock:
3+ units in stock - ready to ship.
Quantity:

FAST SHIPPING

Orders ship same day

HUGE INVENTORY

Thousands of parts in stock

TRUSTED BY CONTRACTORS

Reliable products & service

24/7 ORDERING

Order anytime, anywhere

Description

Honeywell ASD-PL3-BP

Models ASD-PL3 and ASD-PL3-IV are plug-in-type smoke sensors that combine a photoelectronic sensing chamber with addressable-analog communications.
The sensors transmit an analog representation of smoke density over a communication line to a control panel. Rotary dial switches are provided for setting the sensor’s address.

Two LEDs on the sensor a r e controlled by the panel to indicate sensor status.
An output is provided for connection to an optional remote LED annunciator (P/N RA100Z).
Gamewell-FCI panels offer different feature sets across different models. Certain features of the photoelectric sensors may – available on some control panels. ASD-PL3 will support only Velociti® Series protocol mode. ASD-PL3-IV will support  Velociti or CLIP (Classic Loop Interface Protocol) mode. The possible features available if supported by the control panel are:
1. The sensor’s LEDs can operate in three ways—on, off, and blinking. And they can – set to red, green, or amber. This – controlled by the panel.
2. The remote output may – synchronized to the LED operation or controlled independently of the LEDs.
3. Devices are point addressable up to 159 addresses.
Please refer to the operation manual for the UL-listed control panel for specific operations. The photoelectric sensors require compatible addressable communications to function properly. Connect these sensors to listed-compatible control panels only.

Honeywell ASD-PL3-BP

All wiring must – installed in compliance with the National Electrical Code, and applicable local codes. And any special requirements of the Authority Having Jurisdiction. Proper wire gauges should – used. The installation wires should – color-coded to limit wiring mistakes and ease system troubleshooting. Improper connections will prevent a system from responding properly in the event of a fire.

Datasheet

Relative Item

Additional information

Weight 4 lbs
Dimensions 16 × 7 × 7 in

Reviews

There are no reviews yet.

Be the first to review “Honeywell ASD-PL3-BP Smoke Detector”

Your email address will not be published. Required fields are marked *

Payment & Security

Your Payment information is processed securely. We do not store credit card details, nor have access to your credit card information.

CUSTOMER TESTIMONIALS

What Our Customers Say

Can't find it?

    Select at least 2 products
    to compare