Edwards SIGA-OSD Signature Optica Intelligent Addressable Optical Detector Head – White

The Edwards SIGA-OSD is an intelligent addressable optical detector head from the Edwards EST Signature Optica Series. Designed for compatible Edwards fire alarm systems, this professional detection device uses advanced dual-wavelength optical sensing technology to identify airborne smoke particles associated with combustion.

Furthermore, the Edwards SIGA-OSD incorporates intelligent signal processing, automatic environmental compensation, electronic addressing, and automatic device mapping.

Its white, low-profile housing supports professional fire detection installations in commercial and institutional buildings.

The manufacturer identifies the SIGA-OSD in datasheet E85001-1001 and documents compliance with UL 268, 7th Edition.

Consequently, this model provides an exact-model option for maintaining compatible Edwards Signature Series fire alarm systems.

Advanced Signature Optica Smoke Detection Technology

The Edwards SIGA-OSD uses advanced optical technology to detect smoke associated with developing fires.

Unlike conventional single-wavelength optical sensors, the Signature Optica design uses dual optical wavelengths and multiple detection angles.

These sensing elements evaluate how airborne particles scatter light within the detector’s optical chamber.

Furthermore, the detector’s onboard microprocessor analyzes information from the optical sensors and compares the resulting signals with programmed detection criteria.

This approach helps distinguish smoke associated with fire from certain non-fire airborne particles.

Consequently, the SIGA-OSD supports dependable optical smoke detection while reducing unwanted alarms in suitable applications.

Key Features and Benefits

The Edwards SIGA-OSD offers several features for professional fire alarm installations:

  • Intelligent addressable optical smoke detection.
  • Advanced dual-wavelength optical sensing technology.
  • Multiple optical detection angles for improved particle analysis.
  • Integrated nuisance alarm rejection for certain cooking-related particulates.
  • Manufacturer-documented UL 268, 7th Edition compliance.
  • Compatible with approved Edwards Signature loop controllers.
  • Automatic electronic addressing and device mapping.
  • Support for up to 250 total Signature addresses per compatible loop.
  • Five programmable smoke sensitivity settings.
  • Twenty configurable pre-alarm settings.
  • Automatic day and night sensitivity adjustment.
  • Two levels of environmental compensation.
  • Two levels of dirty detector warning.
  • Continuous self-diagnostics and nonvolatile memory.
  • Bicolor green and red LED status indication.
  • Low-profile white engineering polymer housing.
  • Compatible standard, relay, isolator, and audible mounting bases.
  • Operating voltage range of 15.20–19.95VDC.
  • Low normal operating current of approximately 32 microamps.
  • Manufacturer-documented UL/ULC smoke sensitivity range of 0.5–4.36% obscuration per foot.

Dual-Wavelength Optical Sensing

The Edwards SIGA-OSD incorporates two optical wavelengths to evaluate particles entering its sensing chamber.

Additionally, the detector analyzes light scattering from multiple angles.

These measurements provide more information about airborne particles than a basic single-wavelength photoelectric sensing arrangement.

The onboard processor evaluates the optical readings through digital filtering algorithms.

Furthermore, these algorithms help identify signal patterns commonly associated with nuisance sources.

For example, Edwards identifies improved rejection of certain cooking-related particulates.

However, no detector can eliminate every unwanted alarm or guarantee detection of every possible fire condition.

Proper placement, maintenance, and system programming remain essential.

Intelligent Signature Series Communication

The SIGA-OSD communicates with a compatible Edwards Signature loop controller.

Unlike conventional detectors, Signature Series devices provide individual identification and intelligent communication.

Furthermore, the SIGA-OSD supports electronic addressing without requiring manual rotary address switches.

The detector transmits operating information and alarm conditions through the connected signaling circuit.

Consequently, maintenance personnel can identify individual detector locations and investigate reported conditions.

However, the SIGA-OSD requires a compatible Signature loop controller.

It should not be installed on an unrelated conventional or addressable fire alarm circuit.

Automatic Device Mapping

The Edwards SIGA-OSD supports automatic device mapping through compatible Signature fire alarm systems.

This feature allows the control equipment to identify the relative arrangement of devices on the signaling circuit.

Additionally, the system can recognize certain changes in device placement or wiring configuration.

For example, device mapping can help identify a detector that has been returned to an incorrect location following maintenance.

This capability supports professional fire alarm system servicing.

Nevertheless, automatic mapping requires approved Signature control equipment and appropriate system configuration.

Programmable Smoke Sensitivity

The Edwards SIGA-OSD supports five programmable smoke sensitivity settings.

The manufacturer identifies a sensitivity range of 0.5% to 4.36% obscuration per foot.

Additionally, compatible systems can provide twenty pre-alarm settings.

These options allow qualified technicians to configure detector response according to the approved fire alarm design.

Furthermore, the detector supports automatic day and night sensitivity adjustment when the connected system provides that functionality.

However, not every compatible control panel supports every available feature.

Technicians must verify the exact panel capabilities and applicable programming requirements.

Automatic Environmental Compensation

The SIGA-OSD incorporates automatic environmental compensation to help maintain consistent sensing performance.

Over time, dust and other airborne particles can accumulate inside an optical sensing chamber.

The detector’s intelligent electronics monitor certain changes in the sensing environment.

Furthermore, Edwards provides two levels of environmental compensation and two levels of dirty detector warning.

These functions help maintenance personnel identify detectors requiring inspection or cleaning.

However, environmental compensation does not eliminate the need for periodic maintenance.

Self-Diagnostics and History Storage

The Edwards SIGA-OSD includes continuous self-diagnostic functions.

Its onboard processor monitors operating conditions and evaluates information from the optical sensing elements.

Additionally, the detector includes nonvolatile memory for storing selected information.

These features support troubleshooting and maintenance through compatible fire alarm control equipment.

Furthermore, the detector’s LED indicator provides local operating information.

Nevertheless, qualified technicians must perform the inspection and functional testing required by applicable fire alarm maintenance standards.

Electrical Specifications and Performance

The Edwards SIGA-OSD operates through a compatible Signature signaling circuit.

According to the manufacturer’s technical documentation, its operating voltage range is 15.20–19.95VDC.

Normal operating current is approximately 32 microamps.

Additionally, the detector draws approximately 45 microamps in alarm.

These low-current characteristics support compatible Edwards Signature loop installations.

However, installers must verify loop capacity, wiring requirements, device compatibility, and approved system configuration.

The SIGA-OSD is not a standalone battery-powered residential alarm.

Environmental Operating Requirements

The Edwards SIGA-OSD supports an operating temperature range from 32°F to 120°F (0°C to 49°C).

Additionally, the manufacturer specifies relative humidity from 0% to 93%, non-condensing.

The detector supports air velocities from 0 to 4,000 feet per minute under its documented operating conditions.

These specifications help qualified technicians evaluate suitable installation environments.

However, the detector should not be exposed to conditions beyond the manufacturer’s published ratings.

For specialized duct installations, technicians must also verify the approved mounting arrangement and application requirements.

White Low-Profile Housing

The Edwards SIGA-OSD features a white housing constructed from high-impact engineering polymer.

Its compact circular design supports compatible ceiling-mounted installations.

Furthermore, the detector includes a bicolor LED indicator.

During normal operation, the green LED flashes.

When the detector reports an alarm or active condition, the red LED flashes.

These indicators help maintenance personnel identify operating conditions during inspection and testing.

Additionally, the detector supports installation with approved Edwards Signature mounting bases.

Compatible Mounting Bases and Accessories

The Edwards SIGA-OSD supports several manufacturer-approved Signature Series mounting bases and accessories.

Relevant options include:

  • SIGA-SB: Standard detector mounting base.
  • SIGA-SB4: Four-inch standard mounting base with trim skirt.
  • SIGA-RB: Relay detector mounting base.
  • SIGA-RB4: Four-inch relay mounting base.
  • SIGA-IB: Fault isolator mounting base.
  • SIGA-IB4: Four-inch fault isolator mounting base.
  • SIGA-AB4G: Audible sounder base for fire detectors.
  • SIGA-AB4G-LF: Low-frequency audible sounder base.
  • SIGA-AB4GT: Audible sounder base for compatible fire and CO applications.
  • SIGA-LED: Optional remote alarm indicator.
  • SIGA-TS4: Trim skirt for compatible four-inch bases.
  • SIGA-DMP: Detector mounting plate.
  • SIGA-RTA: Detector removal tool.
  • SIGA-VA: Detector cleaning tool.

These accessories support different approved installation and maintenance arrangements.

However, the SIGA-OSD product designation identifies the detector head itself.

Mounting bases, sounders, trim skirts, and additional accessories are separate unless specifically included with the actual product.

Compatibility with Edwards EST Fire Alarm Systems

The Edwards SIGA-OSD is designed for compatible EST Signature Series fire alarm systems.

Its intelligent communication requires an approved Signature loop controller.

Furthermore, the detector supports automatic mapping, programmable sensitivity, environmental compensation, and intelligent alarm reporting.

However, compatibility depends on the exact fire alarm control panel, loop controller, firmware, and approved system configuration.

The SIGA-OSD should not be assumed interchangeable with every Edwards Signature detector.

Additionally, the SIGA-OSD differs from other Signature Optica models.

The SIGA-OSHD incorporates additional heat sensing, while the SIGA-OSCD adds carbon monoxide sensing.

The SIGA-OSD itself is an optical smoke-sensing detector and does not include those additional detection functions.

Commercial and Institutional Applications

The Edwards SIGA-OSD supports professional fire detection in suitable commercial and institutional buildings.

Potential applications include:

  • Commercial office buildings
  • Educational facilities and universities
  • Healthcare and institutional properties
  • Hotels and hospitality buildings
  • Retail and commercial premises
  • Public corridors and common areas
  • Warehouses and suitable storage facilities
  • Existing Edwards EST Signature installations
  • Professional fire alarm maintenance projects

Furthermore, its advanced optical sensing technology makes it relevant to approved applications where nuisance alarm resistance is important.

Nevertheless, qualified fire alarm professionals must evaluate detector placement, environmental conditions, control panel compatibility, and applicable safety requirements.

Genuine Edwards Signature Optica Equipment

The Edwards SIGA-OSD is a manufacturer-documented intelligent optical detector head.

Its combination of dual-wavelength sensing, multiple detection angles, automatic device mapping, programmable sensitivity, and self-diagnostics supports compatible professional fire alarm installations.

Edwards identifies the model in datasheet E85001-1001 and installation sheet P/N 3102595-EN.

The manufacturer also documents applicable UL 268, UL 268A, and CAN/ULC-S529 standards.

However, these references do not independently establish the certification markings, physical condition, or remaining service life of an individual detector.

Before purchasing, review the actual product photographs to confirm the complete SIGA-OSD model number, manufacturer identification, date code, housing condition, and included accessories.

Finally, qualified fire alarm professionals should verify exact-model compatibility, inspect the detector, install it according to Edwards instructions, and perform appropriate functional testing before placing the equipment into service.

SIGA-OSD Datasheet

Additional information

Weight 1 lbs
Dimensions 5 × 5 × 5 in
Brand

Reviews

There are no reviews yet.

Be the first to review “Honeywell Edwards SIGA-OSD Addressable Detector Head”

Your email address will not be published. Required fields are marked *

Payment & Security

Your Payment information is processed securely. We do not store credit card details, nor have access to your credit card information.

Honeywell Edwards SIGA-OSD Addressable Detector Head

SKU SIGA-OSD Category Brand:
Price:
$75.00
Shipping calculated at checkout | Purchase & earn 75 points!
Stock:
802+ units in stock - ready to ship.
Quantity:

FAST SHIPPING

Orders ship same day

HUGE INVENTORY

Thousands of parts in stock

TRUSTED BY CONTRACTORS

Reliable products & service

24/7 ORDERING

Order anytime, anywhere

Description

Edwards SIGA-OSD Signature Optica Intelligent Addressable Optical Detector Head – White

The Edwards SIGA-OSD is an intelligent addressable optical detector head from the Edwards EST Signature Optica Series. Designed for compatible Edwards fire alarm systems, this professional detection device uses advanced dual-wavelength optical sensing technology to identify airborne smoke particles associated with combustion.

Furthermore, the Edwards SIGA-OSD incorporates intelligent signal processing, automatic environmental compensation, electronic addressing, and automatic device mapping.

Its white, low-profile housing supports professional fire detection installations in commercial and institutional buildings.

The manufacturer identifies the SIGA-OSD in datasheet E85001-1001 and documents compliance with UL 268, 7th Edition.

Consequently, this model provides an exact-model option for maintaining compatible Edwards Signature Series fire alarm systems.

Advanced Signature Optica Smoke Detection Technology

The Edwards SIGA-OSD uses advanced optical technology to detect smoke associated with developing fires.

Unlike conventional single-wavelength optical sensors, the Signature Optica design uses dual optical wavelengths and multiple detection angles.

These sensing elements evaluate how airborne particles scatter light within the detector’s optical chamber.

Furthermore, the detector’s onboard microprocessor analyzes information from the optical sensors and compares the resulting signals with programmed detection criteria.

This approach helps distinguish smoke associated with fire from certain non-fire airborne particles.

Consequently, the SIGA-OSD supports dependable optical smoke detection while reducing unwanted alarms in suitable applications.

Key Features and Benefits

The Edwards SIGA-OSD offers several features for professional fire alarm installations:

  • Intelligent addressable optical smoke detection.
  • Advanced dual-wavelength optical sensing technology.
  • Multiple optical detection angles for improved particle analysis.
  • Integrated nuisance alarm rejection for certain cooking-related particulates.
  • Manufacturer-documented UL 268, 7th Edition compliance.
  • Compatible with approved Edwards Signature loop controllers.
  • Automatic electronic addressing and device mapping.
  • Support for up to 250 total Signature addresses per compatible loop.
  • Five programmable smoke sensitivity settings.
  • Twenty configurable pre-alarm settings.
  • Automatic day and night sensitivity adjustment.
  • Two levels of environmental compensation.
  • Two levels of dirty detector warning.
  • Continuous self-diagnostics and nonvolatile memory.
  • Bicolor green and red LED status indication.
  • Low-profile white engineering polymer housing.
  • Compatible standard, relay, isolator, and audible mounting bases.
  • Operating voltage range of 15.20–19.95VDC.
  • Low normal operating current of approximately 32 microamps.
  • Manufacturer-documented UL/ULC smoke sensitivity range of 0.5–4.36% obscuration per foot.

Dual-Wavelength Optical Sensing

The Edwards SIGA-OSD incorporates two optical wavelengths to evaluate particles entering its sensing chamber.

Additionally, the detector analyzes light scattering from multiple angles.

These measurements provide more information about airborne particles than a basic single-wavelength photoelectric sensing arrangement.

The onboard processor evaluates the optical readings through digital filtering algorithms.

Furthermore, these algorithms help identify signal patterns commonly associated with nuisance sources.

For example, Edwards identifies improved rejection of certain cooking-related particulates.

However, no detector can eliminate every unwanted alarm or guarantee detection of every possible fire condition.

Proper placement, maintenance, and system programming remain essential.

Intelligent Signature Series Communication

The SIGA-OSD communicates with a compatible Edwards Signature loop controller.

Unlike conventional detectors, Signature Series devices provide individual identification and intelligent communication.

Furthermore, the SIGA-OSD supports electronic addressing without requiring manual rotary address switches.

The detector transmits operating information and alarm conditions through the connected signaling circuit.

Consequently, maintenance personnel can identify individual detector locations and investigate reported conditions.

However, the SIGA-OSD requires a compatible Signature loop controller.

It should not be installed on an unrelated conventional or addressable fire alarm circuit.

Automatic Device Mapping

The Edwards SIGA-OSD supports automatic device mapping through compatible Signature fire alarm systems.

This feature allows the control equipment to identify the relative arrangement of devices on the signaling circuit.

Additionally, the system can recognize certain changes in device placement or wiring configuration.

For example, device mapping can help identify a detector that has been returned to an incorrect location following maintenance.

This capability supports professional fire alarm system servicing.

Nevertheless, automatic mapping requires approved Signature control equipment and appropriate system configuration.

Programmable Smoke Sensitivity

The Edwards SIGA-OSD supports five programmable smoke sensitivity settings.

The manufacturer identifies a sensitivity range of 0.5% to 4.36% obscuration per foot.

Additionally, compatible systems can provide twenty pre-alarm settings.

These options allow qualified technicians to configure detector response according to the approved fire alarm design.

Furthermore, the detector supports automatic day and night sensitivity adjustment when the connected system provides that functionality.

However, not every compatible control panel supports every available feature.

Technicians must verify the exact panel capabilities and applicable programming requirements.

Automatic Environmental Compensation

The SIGA-OSD incorporates automatic environmental compensation to help maintain consistent sensing performance.

Over time, dust and other airborne particles can accumulate inside an optical sensing chamber.

The detector’s intelligent electronics monitor certain changes in the sensing environment.

Furthermore, Edwards provides two levels of environmental compensation and two levels of dirty detector warning.

These functions help maintenance personnel identify detectors requiring inspection or cleaning.

However, environmental compensation does not eliminate the need for periodic maintenance.

Self-Diagnostics and History Storage

The Edwards SIGA-OSD includes continuous self-diagnostic functions.

Its onboard processor monitors operating conditions and evaluates information from the optical sensing elements.

Additionally, the detector includes nonvolatile memory for storing selected information.

These features support troubleshooting and maintenance through compatible fire alarm control equipment.

Furthermore, the detector’s LED indicator provides local operating information.

Nevertheless, qualified technicians must perform the inspection and functional testing required by applicable fire alarm maintenance standards.

Electrical Specifications and Performance

The Edwards SIGA-OSD operates through a compatible Signature signaling circuit.

According to the manufacturer’s technical documentation, its operating voltage range is 15.20–19.95VDC.

Normal operating current is approximately 32 microamps.

Additionally, the detector draws approximately 45 microamps in alarm.

These low-current characteristics support compatible Edwards Signature loop installations.

However, installers must verify loop capacity, wiring requirements, device compatibility, and approved system configuration.

The SIGA-OSD is not a standalone battery-powered residential alarm.

Environmental Operating Requirements

The Edwards SIGA-OSD supports an operating temperature range from 32°F to 120°F (0°C to 49°C).

Additionally, the manufacturer specifies relative humidity from 0% to 93%, non-condensing.

The detector supports air velocities from 0 to 4,000 feet per minute under its documented operating conditions.

These specifications help qualified technicians evaluate suitable installation environments.

However, the detector should not be exposed to conditions beyond the manufacturer’s published ratings.

For specialized duct installations, technicians must also verify the approved mounting arrangement and application requirements.

White Low-Profile Housing

The Edwards SIGA-OSD features a white housing constructed from high-impact engineering polymer.

Its compact circular design supports compatible ceiling-mounted installations.

Furthermore, the detector includes a bicolor LED indicator.

During normal operation, the green LED flashes.

When the detector reports an alarm or active condition, the red LED flashes.

These indicators help maintenance personnel identify operating conditions during inspection and testing.

Additionally, the detector supports installation with approved Edwards Signature mounting bases.

Compatible Mounting Bases and Accessories

The Edwards SIGA-OSD supports several manufacturer-approved Signature Series mounting bases and accessories.

Relevant options include:

  • SIGA-SB: Standard detector mounting base.
  • SIGA-SB4: Four-inch standard mounting base with trim skirt.
  • SIGA-RB: Relay detector mounting base.
  • SIGA-RB4: Four-inch relay mounting base.
  • SIGA-IB: Fault isolator mounting base.
  • SIGA-IB4: Four-inch fault isolator mounting base.
  • SIGA-AB4G: Audible sounder base for fire detectors.
  • SIGA-AB4G-LF: Low-frequency audible sounder base.
  • SIGA-AB4GT: Audible sounder base for compatible fire and CO applications.
  • SIGA-LED: Optional remote alarm indicator.
  • SIGA-TS4: Trim skirt for compatible four-inch bases.
  • SIGA-DMP: Detector mounting plate.
  • SIGA-RTA: Detector removal tool.
  • SIGA-VA: Detector cleaning tool.

These accessories support different approved installation and maintenance arrangements.

However, the SIGA-OSD product designation identifies the detector head itself.

Mounting bases, sounders, trim skirts, and additional accessories are separate unless specifically included with the actual product.

Compatibility with Edwards EST Fire Alarm Systems

The Edwards SIGA-OSD is designed for compatible EST Signature Series fire alarm systems.

Its intelligent communication requires an approved Signature loop controller.

Furthermore, the detector supports automatic mapping, programmable sensitivity, environmental compensation, and intelligent alarm reporting.

However, compatibility depends on the exact fire alarm control panel, loop controller, firmware, and approved system configuration.

The SIGA-OSD should not be assumed interchangeable with every Edwards Signature detector.

Additionally, the SIGA-OSD differs from other Signature Optica models.

The SIGA-OSHD incorporates additional heat sensing, while the SIGA-OSCD adds carbon monoxide sensing.

The SIGA-OSD itself is an optical smoke-sensing detector and does not include those additional detection functions.

Commercial and Institutional Applications

The Edwards SIGA-OSD supports professional fire detection in suitable commercial and institutional buildings.

Potential applications include:

  • Commercial office buildings
  • Educational facilities and universities
  • Healthcare and institutional properties
  • Hotels and hospitality buildings
  • Retail and commercial premises
  • Public corridors and common areas
  • Warehouses and suitable storage facilities
  • Existing Edwards EST Signature installations
  • Professional fire alarm maintenance projects

Furthermore, its advanced optical sensing technology makes it relevant to approved applications where nuisance alarm resistance is important.

Nevertheless, qualified fire alarm professionals must evaluate detector placement, environmental conditions, control panel compatibility, and applicable safety requirements.

Genuine Edwards Signature Optica Equipment

The Edwards SIGA-OSD is a manufacturer-documented intelligent optical detector head.

Its combination of dual-wavelength sensing, multiple detection angles, automatic device mapping, programmable sensitivity, and self-diagnostics supports compatible professional fire alarm installations.

Edwards identifies the model in datasheet E85001-1001 and installation sheet P/N 3102595-EN.

The manufacturer also documents applicable UL 268, UL 268A, and CAN/ULC-S529 standards.

However, these references do not independently establish the certification markings, physical condition, or remaining service life of an individual detector.

Before purchasing, review the actual product photographs to confirm the complete SIGA-OSD model number, manufacturer identification, date code, housing condition, and included accessories.

Finally, qualified fire alarm professionals should verify exact-model compatibility, inspect the detector, install it according to Edwards instructions, and perform appropriate functional testing before placing the equipment into service.

SIGA-OSD Datasheet

Additional information

Weight 1 lbs
Dimensions 5 × 5 × 5 in
Brand

Reviews

There are no reviews yet.

Be the first to review “Honeywell Edwards SIGA-OSD Addressable Detector Head”

Your email address will not be published. Required fields are marked *

Payment & Security

Your Payment information is processed securely. We do not store credit card details, nor have access to your credit card information.

CUSTOMER TESTIMONIALS

What Our Customers Say

Select at least 2 products
to compare