Description

The Vigilant GSA-SD is a commercial duct smoke detector designed for compatible Vigilant Signature Series fire alarm systems. It continuously samples air moving through HVAC ductwork to detect smoke and help prevent combustion products from circulating throughout the protected building.

The detector combines a Signature Series smoke sensor with environmental compensation, electronic addressing, self-diagnostics, maintenance reporting, and an integral Form C alarm relay. Its compact SuperDuct design simplifies installation and servicing in confined mechanical spaces. This product is intended exclusively for commercial fire alarm installations.


Product Functions

  • Detects smoke within HVAC ductwork
  • Monitors supply or return air systems
  • Reports alarm conditions to the fire alarm control panel
  • Activates an integral Form C auxiliary relay
  • Supports HVAC shutdown and ancillary equipment control
  • Provides dirty detector and maintenance reporting
  • Supports remote testing and reset
  • Continuously compensates for gradual environmental changes
  • Performs internal self-diagnostics
  • Stores operating and event history in nonvolatile memory

Electrical & System Information

The GSA-SD operates from a compatible Vigilant Signature Data Circuit at 15.2–19.95 VDC. It uses electronic addressing and communicates alarm, trouble, maintenance, and operating information directly to the compatible Signature Loop Controller.

An unsupervised, power-limited Form C alarm relay is provided for controlling HVAC equipment or other approved auxiliary functions. The detector also supports a remote test station or remote alarm LED when required by the installation.


Features

  • Commercial duct smoke detector
  • Signature Series communication
  • Environmental compensation
  • Differential smoke sensing
  • Electronic addressing
  • Dirty detector identification
  • Defective detector reporting
  • Built-in self-diagnostics
  • Nonvolatile event and maintenance history
  • Red alarm and green power LEDs
  • Clear cover for visible status indication
  • Cover tamper monitoring switch
  • Magnet-activated test switch
  • Integral Form C alarm relay
  • Conformally coated circuit board
  • Removable dust filters
  • Low-profile SuperDuct housing

Mounting & Design

The GSA-SD mounts directly to HVAC ductwork and uses a separately ordered sampling tube selected according to duct width. The sampling tube can be installed from either side of the assembly and rotated in 45-degree increments to align the inlet holes correctly with duct airflow.

Its housing measures less than two inches deep, making it suitable for installations with limited clearance. The clear removable cover provides access to the sensing chamber, terminals, filters, sampling tube, and exhaust tube without requiring specialized tools.


Protection & Applications

Suitable for:

  • HVAC Supply Ducts
  • HVAC Return Ducts
  • Air Handling Units
  • Mechanical Rooms
  • Commercial Buildings
  • Hospitals
  • Schools
  • Office Buildings
  • Industrial Facilities
  • Warehouses

A duct smoke detector is intended to monitor smoke movement through an HVAC system and is not a substitute for open-area smoke detection or a complete building fire alarm detection system.


Compatibility

Compatible with:

  • Vigilant Signature Series Fire Alarm Systems
  • Signature Loop Controllers
  • Signature Data Circuits
  • SD-T Series Sampling Tubes
  • SD-TRM Magnetic Remote Test Station
  • SD-TRK Keyed Remote Test Station
  • GSA-LED Remote Alarm Indicator
  • SD-PH Protective Housing
  • SD-GSK Cover Gasket Kit
  • Approved HVAC Shutdown Equipment

Always verify compatibility with the installed Vigilant fire alarm control panel, Signature Loop Controller, sampling tube, duct dimensions, airflow conditions, firmware, and system programming before installation.


Technical Specifications

Manufacturer: Vigilant

Brand Family: Edwards / Kidde Commercial

Model: GSA-SD

Series: SuperDuct Signature Series

Product Type: Duct Smoke Detector

Detection Method: Light-Scattering Smoke Sensing

Communication: Signature Data Circuit

Addressing: Electronic

Operating Voltage: 15.2–19.95 VDC

Standby Current: 45 µA

Alarm Current: 45 µA

Inrush Current: 1 mA

Standalone Alarm Current: 18 mA

Smoke Sensitivity: 0.79%–2.46% Obscuration per Foot

Air Velocity Range: 100–4,000 ft/min

Air Pressure Differential: 0.005–1.00 in. Water Column

Alarm Test Response Time: 5 Seconds

Alarm Relay: One Form C Contact

Relay Rating: 2 A at 30 VDC Resistive

Status Indicators: Red Alarm LED and Green Power LED

Remote Accessories: One Remote Test Station or Remote LED

Wire Size: 14–22 AWG

Dimensions: 8.70 × 5.45 × 1.90 in. (221 × 138 × 48 mm)

Shipping Weight: 2.4 lb. (1.1 kg)

Sampling Tube: Ordered Separately

Application: Indoor Commercial HVAC and Fire Alarm Systems

Listings: UL Listed, ULC Listed, FM Approved, CSFM Listed, and MEA Approved as applicable. Verify the product label and project requirements before installation.


Applications

The Vigilant GSA-SD is designed for commercial fire alarm systems requiring smoke monitoring within HVAC supply or return ductwork. Typical applications include office buildings, hospitals, schools, hotels, warehouses, industrial facilities, retail centers, government properties, and other commercial occupancies using compatible Vigilant Signature Series fire alarm systems.

GSA-SD Datasheet

Additional information

Weight 1 lbs
Dimensions 8 × 6 × 4 in

Reviews

There are no reviews yet.

Be the first to review “Vigilant GSA-SD Duct Smoke Detector”

Your email address will not be published. Required fields are marked *

Payment & Security

Your Payment information is processed securely. We do not store credit card details, nor have access to your credit card information.

Vigilant GSA-SD Duct Smoke Detector

SKU GSA-SD Category Tag Brand:
Price:
$189.00
Shipping calculated at checkout | Purchase & earn 189 points!
Stock:
105+ units in stock - ready to ship.
Quantity:

FAST SHIPPING

Orders ship same day

HUGE INVENTORY

Thousands of parts in stock

TRUSTED BY CONTRACTORS

Reliable products & service

24/7 ORDERING

Order anytime, anywhere

Description

The Vigilant GSA-SD is a commercial duct smoke detector designed for compatible Vigilant Signature Series fire alarm systems. It continuously samples air moving through HVAC ductwork to detect smoke and help prevent combustion products from circulating throughout the protected building.

The detector combines a Signature Series smoke sensor with environmental compensation, electronic addressing, self-diagnostics, maintenance reporting, and an integral Form C alarm relay. Its compact SuperDuct design simplifies installation and servicing in confined mechanical spaces. This product is intended exclusively for commercial fire alarm installations.


Product Functions

  • Detects smoke within HVAC ductwork
  • Monitors supply or return air systems
  • Reports alarm conditions to the fire alarm control panel
  • Activates an integral Form C auxiliary relay
  • Supports HVAC shutdown and ancillary equipment control
  • Provides dirty detector and maintenance reporting
  • Supports remote testing and reset
  • Continuously compensates for gradual environmental changes
  • Performs internal self-diagnostics
  • Stores operating and event history in nonvolatile memory

Electrical & System Information

The GSA-SD operates from a compatible Vigilant Signature Data Circuit at 15.2–19.95 VDC. It uses electronic addressing and communicates alarm, trouble, maintenance, and operating information directly to the compatible Signature Loop Controller.

An unsupervised, power-limited Form C alarm relay is provided for controlling HVAC equipment or other approved auxiliary functions. The detector also supports a remote test station or remote alarm LED when required by the installation.


Features

  • Commercial duct smoke detector
  • Signature Series communication
  • Environmental compensation
  • Differential smoke sensing
  • Electronic addressing
  • Dirty detector identification
  • Defective detector reporting
  • Built-in self-diagnostics
  • Nonvolatile event and maintenance history
  • Red alarm and green power LEDs
  • Clear cover for visible status indication
  • Cover tamper monitoring switch
  • Magnet-activated test switch
  • Integral Form C alarm relay
  • Conformally coated circuit board
  • Removable dust filters
  • Low-profile SuperDuct housing

Mounting & Design

The GSA-SD mounts directly to HVAC ductwork and uses a separately ordered sampling tube selected according to duct width. The sampling tube can be installed from either side of the assembly and rotated in 45-degree increments to align the inlet holes correctly with duct airflow.

Its housing measures less than two inches deep, making it suitable for installations with limited clearance. The clear removable cover provides access to the sensing chamber, terminals, filters, sampling tube, and exhaust tube without requiring specialized tools.


Protection & Applications

Suitable for:

  • HVAC Supply Ducts
  • HVAC Return Ducts
  • Air Handling Units
  • Mechanical Rooms
  • Commercial Buildings
  • Hospitals
  • Schools
  • Office Buildings
  • Industrial Facilities
  • Warehouses

A duct smoke detector is intended to monitor smoke movement through an HVAC system and is not a substitute for open-area smoke detection or a complete building fire alarm detection system.


Compatibility

Compatible with:

  • Vigilant Signature Series Fire Alarm Systems
  • Signature Loop Controllers
  • Signature Data Circuits
  • SD-T Series Sampling Tubes
  • SD-TRM Magnetic Remote Test Station
  • SD-TRK Keyed Remote Test Station
  • GSA-LED Remote Alarm Indicator
  • SD-PH Protective Housing
  • SD-GSK Cover Gasket Kit
  • Approved HVAC Shutdown Equipment

Always verify compatibility with the installed Vigilant fire alarm control panel, Signature Loop Controller, sampling tube, duct dimensions, airflow conditions, firmware, and system programming before installation.


Technical Specifications

Manufacturer: Vigilant

Brand Family: Edwards / Kidde Commercial

Model: GSA-SD

Series: SuperDuct Signature Series

Product Type: Duct Smoke Detector

Detection Method: Light-Scattering Smoke Sensing

Communication: Signature Data Circuit

Addressing: Electronic

Operating Voltage: 15.2–19.95 VDC

Standby Current: 45 µA

Alarm Current: 45 µA

Inrush Current: 1 mA

Standalone Alarm Current: 18 mA

Smoke Sensitivity: 0.79%–2.46% Obscuration per Foot

Air Velocity Range: 100–4,000 ft/min

Air Pressure Differential: 0.005–1.00 in. Water Column

Alarm Test Response Time: 5 Seconds

Alarm Relay: One Form C Contact

Relay Rating: 2 A at 30 VDC Resistive

Status Indicators: Red Alarm LED and Green Power LED

Remote Accessories: One Remote Test Station or Remote LED

Wire Size: 14–22 AWG

Dimensions: 8.70 × 5.45 × 1.90 in. (221 × 138 × 48 mm)

Shipping Weight: 2.4 lb. (1.1 kg)

Sampling Tube: Ordered Separately

Application: Indoor Commercial HVAC and Fire Alarm Systems

Listings: UL Listed, ULC Listed, FM Approved, CSFM Listed, and MEA Approved as applicable. Verify the product label and project requirements before installation.


Applications

The Vigilant GSA-SD is designed for commercial fire alarm systems requiring smoke monitoring within HVAC supply or return ductwork. Typical applications include office buildings, hospitals, schools, hotels, warehouses, industrial facilities, retail centers, government properties, and other commercial occupancies using compatible Vigilant Signature Series fire alarm systems.

GSA-SD Datasheet

Additional information

Weight 1 lbs
Dimensions 8 × 6 × 4 in

Reviews

There are no reviews yet.

Be the first to review “Vigilant GSA-SD Duct Smoke Detector”

Your email address will not be published. Required fields are marked *

Payment & Security

Your Payment information is processed securely. We do not store credit card details, nor have access to your credit card information.

CUSTOMER TESTIMONIALS

What Our Customers Say

Select at least 2 products
to compare